CHAPTER 3: BUILDING BLOCKS
TECHNICAL
obstructions 24 inches (610 mm) minimum.
The
space
shall be permitted to include knee and toe
clearance complying with 306 only at the end of either the base or one arm.
304.4 Door Swing.
Doors shall be permitted to swing into turning
spaces
.
305 Clear Floor or Ground Space
305.1 General.
Clear floor or ground
space
shall comply with 305.
305.2 Floor or Ground Surfaces.
Floor or ground surfaces of a clear floor or ground
space
shall
comply with 302. Changes in level are not permitted.
EXCEPTION:
Slopes not steeper than 1:48 shall be permitted.
305.3 Size.
The clear floor or ground
space
shall be 30 inches (760 mm) minimum by 48 inches (1220
mm) minimum.
Figure 304.3.2
T-Shaped Turning Space
2010 Standards: Titles II and III
-