CHAPTER 4: ACCESSIBLE ROUTES
TECHNICAL
404.2.6 Doors in Series and Gates in Series.
The distance between two hinged or pivoted doors
in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates
swinging into the
space
.
404.2.7 Door and Gate Hardware.
Handles, pulls, latches, locks, and other
operable parts
on doors
and gates shall comply with 309.4.
Operable parts
of such hardware shall be 34 inches (865 mm)
minimum and 48 inches (1220 mm) maximum above the finish floor or ground.
Where sliding doors
are in the fully open position, operating hardware shall be exposed and usable from both sides.
EXCEPTIONS:
1.
Existing locks shall be permitted in any location at existing glazed doors
without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that
are designed with locks that are activated only at the top or bottom rail.
2.
Access gates in barrier walls and fences protecting pools, spas, and hot tubs shall be
permitted to have
operable parts
of the release of latch on self-latching devices at 54 inches
(1370 mm) maximum above the finish floor or ground provided the self-latching devices are not
also self-locking devices and operated by means of a key, electronic opener, or integral
combination lock.
Figure 404.2.6
Doors in Series and Gates in Series
Advisory 404.2.7 Door and Gate Hardware.
Door hardware that can be operated with a
closed fist or a loose grip accommodates the greatest range of users. Hardware that
requires simultaneous hand and finger movements require greater dexterity and
coordination, and is not recommended.