505.7.2 Non-Circular Cross Sections.
Handrail gripping surfaces with a non-circular cross section
shall have a perimeter dimension of 4 inches (100 mm) minimum and 6¼ inches (160 mm)
maximum, and a cross-section dimension of 2¼ inches (57 mm) maximum.
505.8 Surfaces.
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or
abrasive
elements
and shall have rounded edges.
505.9 Fittings.
Handrails shall not rotate within their fittings.
505.10 Handrail Extensions.
Handrail gripping surfaces shall extend beyond and in the same direction
of stair flights and
ramp
runs in accordance with 505.10.
EXCEPTIONS:
1.
Extensions shall not be required for continuous handrails at the inside turn of
switchback or dogleg stairs and
ramps
.
2.
In
assembly areas
, extensions shall not be required for
ramp
handrails in aisles serving seating
where the handrails are discontinuous to provide access to seating and to permit crossovers within
aisles.
3.
In
alterations
, full extensions of handrails shall not be required where such extensions would be
hazardous due to plan configuration.
505.10.1 Top and Bottom Extension at Ramps.
Ramp
handrails shall extend horizontally above
the landing for 12 inches (305 mm) minimum beyond the top and bottom of
ramp
runs.
Extensions
shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an
adjacent
ramp
run.