Architectural Research Consultants, Incorporated
Return CIP List
Return Facility Menu
Return Main Menu
Capital Improvement Project
CIP for Kent Hall - ID No: 033.19.1
Building No.
033
Facility
Kent Hall [
Floor Plans
]
Room/Space
Restrooms/Drinking Fountains/Sinks
Space Type
Urgency
High
Priority Level
Priority-Two
Difficulty
Difficulty Level 1: Readily Achievable
CIP Tracking
In House M&O
Survey No
3.28
Related ADA Code Lookups:
[
308.2.2
]
Project No.
19
Project Name
Restroom Improvements
Project Description
Toilet accessories are not ADA compliant. Mount mirror at 40 inches above floor. Mount the coat hooks no less than 15 inches and no more than 48" inches above the floor. The soap dispenser above the counter should be no more than 44 inches above floor. The sanitary napkin disposal should be mounted no higher than 48 inches and 7 to 9 inches from the front of the toilet and must not block access to the grab bars.
No.
Description
Cost:
Quantity
Unit
CIP Code
Severity
MACC
TPC
Relocate accessories
$6579.36
$8816.34