Architectural Research Consultants, Incorporated
Return CIP List
Return Facility Menu
Return Main Menu
Capital Improvement Project
CIP for Branson Library - ID No: 278.58.1
Building No.
278
Facility
Branson Library [
Floor Plans
]
Room/Space
4th Floor Ramp 409 - handrails
Space Type
Coordor
Urgency
High
Priority Level
Priority-One
Difficulty
Difficulty Level 1: Readily Achievable
CIP Tracking
In House M&O
Survey No
2.18
Related ADA Code Lookups:
[
405.8
]
Project No.
58
Project Name
Interior Accessible Route Improvements
Project Description
The ramp at room 409 is approximately 8 percent, 31 feet long, has risers above 6 inches, and there are no handrails installed. Install two handrails to comply with ADA requirements.
No.
Description
Cost:
Quantity
Unit
CIP Code
Severity
MACC
TPC
Install handrails
$10190.32
$13655.03