Architectural Research Consultants, Incorporated
Return CIP List
Return Facility Menu
Return Main Menu
Capital Improvement Project
CIP for Music Building - ID No: 389.4.1
Building No.
389
Facility
Music Building [
Floor Plans
]
Room/Space
Ramps
Space Type
Urgency
High
Priority Level
Priority-Two
Difficulty
Difficulty Level 2: More Difficult to Achieve
CIP Tracking
RFP
Survey No
2.2
Related ADA Code Lookups:
[
206.2.4
]
Project No.
4
Project Name
Interior Accessible Route Improvements
Project Description
The ramp in H100 has no landing at the bottom where it joins the historic structure to the west and Ramp in H101 has no landing adjacent to the doors. Re-work the ramp to provide required landings and railings in ADA compliant configuration.
No.
Description
Cost:
Quantity
Unit
CIP Code
Severity
MACC
TPC
Replace ramp
$7634.00
$7724.84