Architectural Research Consultants, Incorporated
Return CIP List
Return Facility Menu
Return Main Menu
Capital Improvement Project
CIP for English Building - ID No: 364.22.1
Building No.
364
Facility
English Building [
Floor Plans
]
Room/Space
Southwest entry
Space Type
Entrance
Urgency
Low
Priority Level
Priority-Two
Difficulty
Difficulty Level 2: More Difficult to Achieve
CIP Tracking
In House M&O
Survey No
1.50
Related ADA Code Lookups:
[
404.2.6
]
Project No.
22
Project Name
Exterior Entry Modifications
Project Description
The southwest entry vestibule is too small to be an accessible entry, the clear space between the doors is only 32 inches. Renovate the vestibule to provide an ADA compliant clear space between the doors.
No.
Description
Cost:
Quantity
Unit
CIP Code
Severity
MACC
TPC
Enlarge vestibule
$9877.76
$13236.20